- HCF Ceiling Filter Media: synthetic fiber as different structure for different density
- Submit Order
Fire resistance standard: UL-900 Class2
It possible add galvanized steel, aluminum alloy frame and metal mesh in the air outlet side
SpecificationFeatures
Frame structureApplication
Model | HCF-600G |
Common Size | 22mmT×1.6m×20m 22mmT×2m×20m |
Ingredient | Polyester |
Gram Weight | 600g/m2 |
Capacity of Dust Arrestment | 400g/m2 |
Norm Velocity | 0.26m/s |
Heat Resistance | 120oC |
Fire-protection Rating | Class F1 DIN53438 |
Average Trapping Efficiency | 97~99% |
Initial Pressure Drop | 26Pa |
Final Pressure Drop | 400Pa |
◆Using polyester, polyamide, nylon, etc. chemical synthetic fibers, in accordance with different diameter and density of them, make into a conformation of the increase in density by non-woven process, it has a property of high permeability, low initial resistance and high dust collection rate
◆Using different melting point of exterior and interior of the fiber,thick and thin fibers was fused together by hot-melt fibers, without any chemical adhesives
◆The contacts between the fibers are strong. The integration between the fibers is closer, and the fiber is not easy to shed.
◆Low flammability, fire resistance measures up to Deutsche industry norm DIN53438F1
◆Can be washed repeatedly
◆Can be with galvanized steel or aluminum alloy frame and also expanded metal on the exhaust side, to effectively prevent deformation of the separator under high-speed airflow
◆Can be with galvanized steel or aluminum alloy frame
◆Using different melting point of exterior and interior of the fiber,thick and thin fibers was fused together by hot-melt fibers, without any chemical adhesives
◆The contacts between the fibers are strong. The integration between the fibers is closer, and the fiber is not easy to shed.
◆Low flammability, fire resistance measures up to Deutsche industry norm DIN53438F1
◆Can be washed repeatedly
◆Can be with galvanized steel or aluminum alloy frame and also expanded metal on the exhaust side, to effectively prevent deformation of the separator under high-speed airflow
◆Can be with galvanized steel or aluminum alloy frame
Model | Eff(%) | Capacity of Dust Arrestment | Initial Pressure Drop |
22mmTx1.8mx20m | M5 | 400g/m² | 26Pa |
22mmTx2mx20m |
◆Apply to the air supply system on top of the spraying-banking booth in painting factory to safeguard a high degree of cleanliness and air-distribution uniformity. Trapping small dust particles and preventing pollution of paint.