There is no doubt that cleanroom applied in many areas due to special needs. The cleanroom should have good design to meet different requirements and it should be built in a suitable place.
Now let's have a brief learning about cleanroom design and construction.
Firstly, let's talk about the design of Cleanroom Design and construction. Clean room uses the design of arc angle which is more suitable for cleanroom. The system can automatically controls operation and it has two-door electronic interlocking setting, a photoelectric sensor, a one-way channel air shower. After closing infrared sensors, someone should blow shower. It uses the technology of cold-rolled steel the outer surface electrostatic spray in overall production and. Door, floor, nozzles of cleanroom are made of stainless steel which can stop corrosion. What's more, it uses the early, high level filtration system with HEPA filter which has the efficiency of 99.99% to ensure the purification level. It also uses EVA sealing material of high airtight performance.
Secondly, let's talk about the construction of cleanroom design and construction. Clean room should be built in the place where atmospheric dust concentration is low and the regional natural environment is better. Clean room should be far away from the railway and docks, airports, transportation routes and distribute large amounts of dust and harmful gas factory, storehouse, yard and other regions of serious air pollution, vibration or noise. The cleanroom should be built be far away from the serious air pollution source or it should be built in its maximum frequency of the upwind side or the annual minimum wind frequency leeward side. Clean room shall be arranged inside the factory where the environment is clean or the place where the stream of cargo and people can't go cross. The clean room layout must be reasonable and compact. Clean room or clean area only prepares necessary equipment and the studio which has classification of air cleanliness requirements. The prerequisite to meet the requirements of the production process, clean room or clean areas should be close to the high air conditioning room. Cleanroom with the same air cleanliness levels is suitable for centralized arrangement. Studio of low air cleanliness level is suitable for the arrangement that near the clean area. Cleanroom with high indoor air cleanliness requirements shall be arranged on the upwind side, otherwise it should be near the return air inlet.
These are two aspects of Cleanroom air filters design and construction. With the development of technology and science, the cleanroom can be more advanced. If you want to learn more information about cleanroom design and construction, you can search more information on the internet.